TCG 3016 Efficient digital technology

- Output range from 400 kW el to 1,000 kW el
- Best efficiency: electrical efficiency up to 43%
- Low gas consumption, flexible fuel use, suitable for all gas types: natural gas, biogas, landfill gas, sewage gas, mine gas, hydrogen admixture and other gases
- MWM retrofit kits are available in two versions to convert to operate with hydrogen mixtures of up to 20 vol% and up to 25 vol%
- Dramatically reduce installation and operating costs
- Improve reliability and availability through increased robustness
- Longer maintenance intervals and low maintenance costs
- Very low lubricating oil consumption and easy oil management for the operator
TCG 3016 V16 (S = High Density) is optimized specifically for the 1 MWel capacity range and offers high stress tolerance for optimal availability and long service life
Technical data 50 Hz
TCG 3016
Unit
V08
V12
V16
V16S
Bore x stroke
mm
132/160
132/160
132/160
132/160
Displacement
dm3
17.5
26.3
35.0
35.0
Speed
min-1
1,500
1,500
1,500
1,500
Mean piston speed
m/s
8.0
8.0
8.0
8.0
Length 1)
mm
3,100
3,830
4,200
4,200
Width 1)
mm
1,780
1,780
1,780
1,780
Height 1)
mm
2,150
2,150
2,150
2,150
Dry weight genset
kg
5,720
7,000
8,070
8,560
Natural gas applications
NOx ≤ 500 mg/Nm3 2)
TCG 3016
單位Unit
V08
V12
V16
V16S
Configuration
P 5)
P 5)
P 5)
S 6)
Electrical power 3)
kW
400
600
800
1,000
Mean effective pressure
bar
18.9
18.9
18.8
23.5
Thermal output 4) ±8%
kW
404
617
819
1,123
Electrical efficiency 3)
%
43.1
43.4
43.6
41.5
Thermal efficiency 3)
%
43.6
44.6
44.6
46.6
Total efficiency 3)
%
86.7
88.0
88.2
88.1
1) These are the shipping dimensions of the generator set, individually installed components must also be taken into account.2) NOx ≤ 500 mg/Nm3; dry flue gas with 5% O2 content.
3) According to ISO standard 3046-1, U= 0.4 kV, 50 HZ, cosphi = 1.0, MN=70 (V08, V12, V16)
Or natural gas with MN=80 (V16 model S) or sewage biogas with MN=134.4) The combustion exhaust gases are cooled to 120°C for natural gas and to 150°C for biogas.
5) P = Highly efficient model. Focus on high electrical efficiency.
6) S = High power model. Increased power density.
The values given in the above data sheets are for reference only and are non-binding. Please refer to the information in the quotation.
TCG 3016 Power plant 3D simulation video :
If you have any needs, please contact us
Welcome to Zhenyi International Power Co., Ltd.