Home
1
Products2
Natural Gas Generator Catalog Natural Gas Generator Catalog https://www.titanpower.com.tw/en/product_1573500.html Natural Gas Generator Contents Index(Click on the brand name text to open the sales page of the label)瓦錫蘭  WARTSILATWG Series natural gas generator 三菱   MITSUBISHITMG Series natural gas generator新瀉  NIIGATA IHITNG Series natural gas generator洋馬 YANMARTYG Series natural gas generator大發    DAIHATSUTDG Series natural gas generator卡特彼勒 CAT Caterpillar 開拓重工 TCG Series natural gas generator曼海姆 MWMTMWG Series natural gas generator顏巴赫 INNIO 詹巴赫 JenbacherTJG Series natural gas generatorIf you have any generator needs, please feel free to email and call us.Welcome to Zhenyi International Power Co., Ltd. 1573500
5 1
Natural Gas Generator Contents Index(Click on the brand name text to open the sales page of the label)瓦錫蘭  WARTSILATWG Series natural gas generator 三菱   MITSUBISHITMG Series natural gas generator新瀉  NIIGATA IHITNG Series natural gas generator洋馬 YANMARTYG Series natural gas generator大發    DAIHATSUTDG Series natural gas generator卡特彼勒 CAT Caterpillar 開拓重工 TCG Series natural gas generator曼海姆 MWMTMWG Series natural gas generator顏巴赫 INNIO 詹巴赫 JenbacherTJG Series natural gas generatorIf you have any generator needs, please feel free to email and call us.Welcome to Zhenyi International Power Co., Ltd.
www.
TWD http://schema.org/InStock https://www.titanpower.com.tw/en/product_1573500.html 2024-03-26 0
Natural Gas Generator Catalog
Denyo DCA-60LSIE Natural gas generator 50Hz 50kVA 60Hz 60kVA Denyo DCA-60LSIE Natural gas generator 50Hz 50kVA 60Hz 60kVA https://www.titanpower.com.tw/en/product_1600738.html                                       DCA-60LSIE Natural gas generator Alternator specifications : Denyo Brushless alternator DCA-60LSIE Phase Three-phase (4-wire type) Single phase (3-wire type) Output Rating kVA 50 60 28.9 34.6 Rated voltage V 200/400 220/44 100/200 110/220 Rated current A 144/72.2 157/78.7 144 157 Frequency Hz 50 60 50 60 Engine BJ-4JJ1X  Output Rating 47.9kW 1500min-1 57.1kW 1800min-1 Bore ×Stroke 4-95.4x104.9mm Fuel ASTM No. 2 Diesel Fuel or Equivalent Dimensions  mm  L2090 x W980 x H1350 Dry Weight  kg 1260 Alternator photo sharing : If you have any needs, please contact usZhenyi International Power Co., Ltd. welcomes you 1600738
5 1
                                      DCA-60LSIE Natural gas generator Alternator specifications : Denyo Brushless alternator DCA-60LSIE Phase Three-phase (4-wire type) Single phase (3-wire type) Output Rating kVA 50 60 28.9 34.6 Rated voltage V 200/400 220/44 100/200 110/220 Rated current A 144/72.2 157/78.7 144 157 Frequency Hz 50 60 50 60 Engine BJ-4JJ1X  Output Rating 47.9kW 1500min-1 57.1kW 1800min-1 Bore ×Stroke 4-95.4x104.9mm Fuel ASTM No. 2 Diesel Fuel or Equivalent Dimensions  mm  L2090 x W980 x H1350 Dry Weight  kg 1260 Alternator photo sharing : If you have any needs, please contact usZhenyi International Power Co., Ltd. welcomes you
www.
TWD http://schema.org/InStock https://www.titanpower.com.tw/en/product_1600738.html 2024-03-26 0
Denyo DCA-60LSIE Natural gas generator 50Hz 50kVA 60Hz 60kVA
TMG Series MITSUBISHI Natural Gas Generator Set TMG Series MITSUBISHI Natural Gas Generator Set https://www.titanpower.com.tw/en/product_1350594.html When you need, please contact usWelcome to Zhenyi International Power Co., Ltd. 1350594
5 1
When you need, please contact usWelcome to Zhenyi International Power Co., Ltd.
www.
TWD http://schema.org/InStock https://www.titanpower.com.tw/en/product_1350594.html 2024-03-26 0
TMG Series MITSUBISHI Natural Gas Generator Set
TNG Series NIIGATA Natural Gas Generator Set TNG Series NIIGATA Natural Gas Generator Set https://www.titanpower.com.tw/en/product_1350595.html NIIGATA Natural Gas GeneratorNatural Gas Generator Catalogue DownloadLink to natural gas generator directoryIf you have any generator needs, please feel free to contact usWelcome to Zhenyi International Power Co., Ltd 1350595
5 1
NIIGATA Natural Gas GeneratorNatural Gas Generator Catalogue DownloadLink to natural gas generator directoryIf you have any generator needs, please feel free to contact usWelcome to Zhenyi International Power Co., Ltd
www.
TWD http://schema.org/InStock https://www.titanpower.com.tw/en/product_1350595.html 2024-03-26 0
TNG Series NIIGATA Natural Gas Generator Set
TYG Series YANMAR Natural Gas Generator Set TYG Series YANMAR Natural Gas Generator Set https://www.titanpower.com.tw/en/product_1350598.html YANMAR Natural Gas GeneratorWhen you need, please contact usWelcome to Zhenyi International Power Co., Ltd. 1350598
5 1
YANMAR Natural Gas GeneratorWhen you need, please contact usWelcome to Zhenyi International Power Co., Ltd.
www.
TWD http://schema.org/InStock https://www.titanpower.com.tw/en/product_1350598.html 2024-03-26 0
TYG Series YANMAR Natural Gas Generator Set
TDG Series DAIHATSU Natural Gas Generator Set TDG Series DAIHATSU Natural Gas Generator Set https://www.titanpower.com.tw/en/product_1350601.html DAIHATSU Natural Gas GeneratorWhen you need, please contact usWelcome to Zhenyi International Power Co., Ltd. 1350601
5 1
DAIHATSU Natural Gas GeneratorWhen you need, please contact usWelcome to Zhenyi International Power Co., Ltd.
www.
TWD http://schema.org/InStock https://www.titanpower.com.tw/en/product_1350601.html 2024-03-26 0
TDG Series DAIHATSU Natural Gas Generator Set
WARTSILA Gas Generator 18V34SG WARTSILA Gas Generator 18V34SG https://www.titanpower.com.tw/en/product_1582658.html           WARTSILA 18V34SG Gas Generator The Wärtsilä 34SG is a four-stroke, Mars-ignition, lean-burn gas engine generator set.The agility and flexibility of the Wärtsilä 34SG generator set make it an excellent choice for flexible base load and balanced renewable energy applications.It also offers a unique quick-start feature that responds quickly to the fluctuations inherent in renewable energy generation. WARTSILA Gas Generator 特色 : No start cost, limitations nor degradation in number of starts Compact sizing enables transportation to demanding locations Capable of operating in high altitude Runs on natural gas, biogas, synthetic methanol and is capable of hydrogen blending Minimal water consumption Longer maintenance intervals   WARTSILA Gas Generator 18V34SG Technical data of the gas engine : Wärtsilä 34SG gas engine generating set Cylinder configurations 12, 16, 20V Cylinder bore 340 mm Piston stroke 400 mm Engine speed 750 rpm (50 Hz), 720 rpm (60 Hz) Performance *   20V34SG 16V34SG 12V34SG Rated electrical power (kW) 9 795 (50Hz) 9 388 (60Hz) 7 830 (50Hz) 7 491 (60Hz) 5 840 (50Hz) 5 580 (60Hz) Electrical efficiency (%) 48.9 (50Hz) 48.8 (60Hz) 48.9 (50Hz) 48.7 (60Hz) 48.0 (50Hz) 47.8 (60Hz) Heat rate (kJ/kWh) 7 363 (50Hz) 7 374 (60Hz) 7367 (50Hz) 7396 (60Hz) 7 501 (50Hz) 7 538 (60Hz) Loading and unloading   Connected to grid Full load Regular start time (min:sec) 00:30 < 5 Fast start time (min:sec) 00:30 < 2 Stop time (min) 1 Ramp rate (hot, load/min) > 100% Minimum Load Unit level 10% Plant level 1% * Rated electrical power and electrical efficiencies are given at generator terminals at 100kPa ambient pressure, 25°C suction air temperature and 30% relative humidity, and without engine driven pumps. Power factor 1.0 (site). Electrical efficiency with 5% tolerance. Site conditions, fuel and applicable emission limits may have an impact on performance figures. Please contact Wärtsilä for project-specific performance data. Emission figures for LBF must be evaluated case by case. Catalyst systems are designed based on project specific requirements. Certain fuel components are poisonous for catalyst elements. Maximum amount of these components to be limited in the fuel in applications where catalyst system is installed. Disclaimer: The information contained herein is provided for informational purposes only and may not be incorporated, in whole or in part, into any agreement or proposal. No representation of any kind is made in respect of any information contained herein and Wärtsilä expressly disclaims any responsibility for, and does not guarantee, the correctness or the completeness of the information. The calculations and assumptions included in the information do not necessarily take into account all the factors that could be relevant in a particular case. Information herein shall not be construed as a guarantee or warranty of the performance of any Wärtsilä technology, equipment or installation. WARTSILA Gas Generator Photo : You can refer to the following link: Natural Gas Generator Catalog WARTSILA Natural gas generator WARTSILA heavy oil generators   When you need, please contact usWelcome to Zhenyi International Power Co., Ltd. 1582658
5 1
          WARTSILA 18V34SG Gas Generator The Wärtsilä 34SG is a four-stroke, Mars-ignition, lean-burn gas engine generator set.The agility and flexibility of the Wärtsilä 34SG generator set make it an excellent choice for flexible base load and balanced renewable energy applications.It also offers a unique quick-start feature that responds quickly to the fluctuations inherent in renewable energy generation. WARTSILA Gas Generator 特色 : No start cost, limitations nor degradation in number of starts Compact sizing enables transportation to demanding locations Capable of operating in high altitude Runs on natural gas, biogas, synthetic methanol and is capable of hydrogen blending Minimal water consumption Longer maintenance intervals   WARTSILA Gas Generator 18V34SG Technical data of the gas engine : Wärtsilä 34SG gas engine generating set Cylinder configurations 12, 16, 20V Cylinder bore 340 mm Piston stroke 400 mm Engine speed 750 rpm (50 Hz), 720 rpm (60 Hz) Performance *   20V34SG 16V34SG 12V34SG Rated electrical power (kW) 9 795 (50Hz) 9 388 (60Hz) 7 830 (50Hz) 7 491 (60Hz) 5 840 (50Hz) 5 580 (60Hz) Electrical efficiency (%) 48.9 (50Hz) 48.8 (60Hz) 48.9 (50Hz) 48.7 (60Hz) 48.0 (50Hz) 47.8 (60Hz) Heat rate (kJ/kWh) 7 363 (50Hz) 7 374 (60Hz) 7367 (50Hz) 7396 (60Hz) 7 501 (50Hz) 7 538 (60Hz) Loading and unloading   Connected to grid Full load Regular start time (min:sec) 00:30 < 5 Fast start time (min:sec) 00:30 < 2 Stop time (min) 1 Ramp rate (hot, load/min) > 100% Minimum Load Unit level 10% Plant level 1% * Rated electrical power and electrical efficiencies are given at generator terminals at 100kPa ambient pressure, 25°C suction air temperature and 30% relative humidity, and without engine driven pumps. Power factor 1.0 (site). Electrical efficiency with 5% tolerance. Site conditions, fuel and applicable emission limits may have an impact on performance figures. Please contact Wärtsilä for project-specific performance data. Emission figures for LBF must be evaluated case by case. Catalyst systems are designed based on project specific requirements. Certain fuel components are poisonous for catalyst elements. Maximum amount of these components to be limited in the fuel in applications where catalyst system is installed. Disclaimer: The information contained herein is provided for informational purposes only and may not be incorporated, in whole or in part, into any agreement or proposal. No representation of any kind is made in respect of any information contained herein and Wärtsilä expressly disclaims any responsibility for, and does not guarantee, the correctness or the completeness of the information. The calculations and assumptions included in the information do not necessarily take into account all the factors that could be relevant in a particular case. Information herein shall not be construed as a guarantee or warranty of the performance of any Wärtsilä technology, equipment or installation. WARTSILA Gas Generator Photo : You can refer to the following link: Natural Gas Generator Catalog WARTSILA Natural gas generator WARTSILA heavy oil generators   When you need, please contact usWelcome to Zhenyi International Power Co., Ltd.
www.
TWD http://schema.org/InStock https://www.titanpower.com.tw/en/product_1582658.html 2024-03-26 0
WARTSILA Gas Generator 18V34SG
TWG Series WARTSILA Natural Gas Generator Set TWG Series WARTSILA Natural Gas Generator Set https://www.titanpower.com.tw/en/product_1350604.html WARTSILA Natural Gas Generator When you need, please contact usWelcome to Zhenyi International Power Co., Ltd. 1350604
5 1
WARTSILA Natural Gas Generator When you need, please contact usWelcome to Zhenyi International Power Co., Ltd.
www.
TWD http://schema.org/InStock https://www.titanpower.com.tw/en/product_1350604.html 2024-03-26 0
TWG Series WARTSILA Natural Gas Generator Set
TCG Series Caterpillar Natural Gas Generator Set TCG Series Caterpillar Natural Gas Generator Set https://www.titanpower.com.tw/en/product_1350606.html Caterpillar Natural Gas Generator Caterpillar Natural Gas Generator has various models available for purchase from 400  kwe to 2519  kwe,which is convenient for finding the most suitable model for factory use.When you need, please contact usWelcome to Zhenyi International Power Co., Ltd. 1350606
5 1
Caterpillar Natural Gas Generator Caterpillar Natural Gas Generator has various models available for purchase from 400  kwe to 2519  kwe,which is convenient for finding the most suitable model for factory use.When you need, please contact usWelcome to Zhenyi International Power Co., Ltd.
www.
TWD http://schema.org/InStock https://www.titanpower.com.tw/en/product_1350606.html 2024-03-26 0
TCG Series Caterpillar Natural Gas Generator Set
MWM TCG3016 Natural gas generator MWM TCG3016 Natural gas generator https://www.titanpower.com.tw/en/product_1596758.html MWM professional productionTCG 3016 Efficient Digital Technology Output range from 400 kWel to 1,000 kWel Optimum efficiency: electrical efficiency up to 43 percent Low gas consumption, flexible use of fuel, suitable for all gas types: natural gas, biogas, landfill gas, sewage gas, mine gas, hydrogen admixtures and other gases MWM retrofit kits available in two editions for conversion for operation with hydrogen admixture of up to 20 vol% and up to 25 vol% Greatly reduced installation and operating costs Higher reliability and availability through improved robustness Low maintenance costs due to longer maintenance intervals Very low lubricant consumption and operator-friendly oil management The TCG 3016 V16 (S = High density) is specifically optimized for the 1 MWel capacity range, with high stress tolerance for optimum availability, and long useful life Technical data 50 Hz TCG 3016 單位Unit V08 V12 V16 V16S Bore x stroke mm 132/160 132/160 132/160 132/160 Displacement dm3 17.5 26.3 35.0 35.0 Speed min-1 1,500 1,500 1,500 1,500 Mean piston speed m/s 8.0 8.0 8.0 8.0 Length 1) mm 3,100 3,830 4,200 4,200 Width 1) mm 1,780 1,780 1,780 1,780 Height 1) mm 2,150 2,150 2,150 2,150 Dry weight genset kg 5,720 7,000 8,070 8,560   Natural gas applications NOx ≤ 500 mg/Nm3  2) TCG 3016 Unit V08 V12 V16 V16S  Configuration   P 5) P 5) P 5) S 6) Electrical power 3) kW 400 600 800 1,000 Mean effective pressure bar 18.9 18.9 18.8 23.5 Thermal output 4) ±8% kW 404 617 819 1,123 Electrical efficiency 3) % 43.1 43.4 43.6 41.5 Thermal efficiency 3) % 43.6 44.6 44.6 46.6  Total efficiency 3) % 86.7 88.0 88.2 88.1 1) Transport dimensions for gensets, components set up seperately must be taken into consideration.2) NOx ≤ 500 mg/Nm3; exhaust gas dry at 5 % O2.3) According to ISO 3046-1 at U = 0.4 kV, cosphi = 1.0 for 50 Hz,a minimum methane number of MN 70(V08,V12,V16) and MN 80 (V16 Configuration S) for natural gas and MN 134 (sewage gas) for biogas applications.4) Exhaust gas cooled to 120 °C for natural gas and 150 °C for biogas.5) P = High Efficiency. Optimized for high electrical efficiency6) S = High Density. Increased power density.The values given on these datasheets are for information purposes only and not binding. The information given in the offer is decisive.   TCG 3016 Power Plant 3D Simulation Video:  If you have any needs, please contact usWelcome to Zhenyi International Power Co., Ltd. 1596758
5 1
MWM professional productionTCG 3016 Efficient Digital Technology Output range from 400 kWel to 1,000 kWel Optimum efficiency: electrical efficiency up to 43 percent Low gas consumption, flexible use of fuel, suitable for all gas types: natural gas, biogas, landfill gas, sewage gas, mine gas, hydrogen admixtures and other gases MWM retrofit kits available in two editions for conversion for operation with hydrogen admixture of up to 20 vol% and up to 25 vol% Greatly reduced installation and operating costs Higher reliability and availability through improved robustness Low maintenance costs due to longer maintenance intervals Very low lubricant consumption and operator-friendly oil management The TCG 3016 V16 (S = High density) is specifically optimized for the 1 MWel capacity range, with high stress tolerance for optimum availability, and long useful life Technical data 50 Hz TCG 3016 單位Unit V08 V12 V16 V16S Bore x stroke mm 132/160 132/160 132/160 132/160 Displacement dm3 17.5 26.3 35.0 35.0 Speed min-1 1,500 1,500 1,500 1,500 Mean piston speed m/s 8.0 8.0 8.0 8.0 Length 1) mm 3,100 3,830 4,200 4,200 Width 1) mm 1,780 1,780 1,780 1,780 Height 1) mm 2,150 2,150 2,150 2,150 Dry weight genset kg 5,720 7,000 8,070 8,560   Natural gas applications NOx ≤ 500 mg/Nm3  2) TCG 3016 Unit V08 V12 V16 V16S  Configuration   P 5) P 5) P 5) S 6) Electrical power 3) kW 400 600 800 1,000 Mean effective pressure bar 18.9 18.9 18.8 23.5 Thermal output 4) ±8% kW 404 617 819 1,123 Electrical efficiency 3) % 43.1 43.4 43.6 41.5 Thermal efficiency 3) % 43.6 44.6 44.6 46.6  Total efficiency 3) % 86.7 88.0 88.2 88.1 1) Transport dimensions for gensets, components set up seperately must be taken into consideration.2) NOx ≤ 500 mg/Nm3; exhaust gas dry at 5 % O2.3) According to ISO 3046-1 at U = 0.4 kV, cosphi = 1.0 for 50 Hz,a minimum methane number of MN 70(V08,V12,V16) and MN 80 (V16 Configuration S) for natural gas and MN 134 (sewage gas) for biogas applications.4) Exhaust gas cooled to 120 °C for natural gas and 150 °C for biogas.5) P = High Efficiency. Optimized for high electrical efficiency6) S = High Density. Increased power density.The values given on these datasheets are for information purposes only and not binding. The information given in the offer is decisive.   TCG 3016 Power Plant 3D Simulation Video:  If you have any needs, please contact usWelcome to Zhenyi International Power Co., Ltd.
www.
TWD http://schema.org/InStock https://www.titanpower.com.tw/en/product_1596758.html 2024-03-26 0
MWM TCG3016 Natural gas generator
TMWG Series MWM Natural Gas Generator Set TMWG Series MWM Natural Gas Generator Set https://www.titanpower.com.tw/en/product_1350611.html MWM Natural Gas GeneratorMWM  natural gas generators photo :We also sell used MWM natural gas generators :If you have any generator needs, please contact usZhenyi International Power Co., Ltd. welcomes you 1350611
5 1
MWM Natural Gas GeneratorMWM  natural gas generators photo :We also sell used MWM natural gas generators :If you have any generator needs, please contact usZhenyi International Power Co., Ltd. welcomes you
www.
TWD http://schema.org/InStock https://www.titanpower.com.tw/en/product_1350611.html 2024-03-26 0
TMWG Series MWM Natural Gas Generator Set
TJG Series Jenbacher Natural Gas Generator Set TJG Series Jenbacher Natural Gas Generator Set https://www.titanpower.com.tw/en/product_1350612.html Jenbacher Natural Gas GeneratorNatural Gas Generator Catalogue DownloadLink to natural gas generator directoryIf you have any generator needs, please feel free to contact usWelcome to Zhenyi International Power Co., Ltd 1350612
5 1
Jenbacher Natural Gas GeneratorNatural Gas Generator Catalogue DownloadLink to natural gas generator directoryIf you have any generator needs, please feel free to contact usWelcome to Zhenyi International Power Co., Ltd
www.
TWD http://schema.org/InStock https://www.titanpower.com.tw/en/product_1350612.html 2024-03-26 0
TJG Series Jenbacher Natural Gas Generator Set
https://www.titanpower.com.tw/en/ Zhen Yi Internatial Power Company Limited
鎮億國際有限公司歡迎您!任何發電機問題皆可洽詢,舉凡保養、維修、規劃電力系統、採購合適機型、零件更換、能源永續…等,只要您需要都可詢問喔! 鎮億國際首頁